Showing results: 2401 - 2415 of 5217 items found.
-
TR-MARK III 250V -
Raytech AG
The TR-MARK III 250V is the successor of the famous TR-MARK III. Besides an extended test voltage up to 250V, it offers new features and increased accuracy to make it a perfect system. A color LCD with back lighting and touch screen increases handling and user comfort. Two USB interfaces make it easy to store measurements on external storage devices and transfer easily to a personal computer or download nameplate data of transformer to test.
-
ADC-2575 -
TestVonics, Inc.
TestVonics ADC-2575 Air Data Calibrator is a high accuracy pitot static calibrator. The calibrator is capable of controlling and measuring Altitude and Airspeed pressures with the highest degree of accuracy. The control and measurement range of the test system can meets or exceed requirements for both commercial and military applications. The ADC-2575 is a derivative of the ADC-2550 Series. It features a touchscreen interface, a mid range 23PSIA sensor. It is ideally suited for Automated Test Equipment (ATE) applications.
-
ThermoWorks
Until now you would have spent hundreds more to get this level of accuracy in a NIST-Traceable standards thermometer. Our Reference Thermapen takes lab accuracy into the field. Each unit is factory calibrated at 5 test points and includes a UKAS accredited calibration certificate with test data. A true "system calibration" is performed matching its Platinum RTD sensor and the built-in electronics so all errors are included in the spec.
-
ATI-100 -
Matrix Test Equipment Incorporated
Now, with our ?New? Model ATI-100 you can turn your existing Matrix Signal Generator and Switchable Filter Bank into a full-blown DTS (Distortion Test System). Plug and play is the word, just plug in your Multiple Frequency Signal Generator, Switchable Filter Bank, Spectrum Analyzer, Oscilloscope, Power Meter, Frequency Counter, etc. to allow the following automatic testing with a single insertion of DUT (device under test
-
Shanghai Jiuzhi Electric Co., Ltd.
AC voltage and current test system is used to be the electrical test performed on a component (such as, bushings, arrestors, insulating materials) or high voltage products (such as, high voltage cables, power transformers, instrument transformers, gas insulated switchgears, air insulated switchgears, high voltage insulators and etc) to determine the effectiveness of its insulation. For the safety of high voltage transmission , testing insulation integrity is essential for all high voltage products.
-
PRF-911PT -
Prostat Corporation
The PRF-911 Concentric Ring is to be attached to the PRS-801B Resistance System included in this Packaging Test Kit. This system will also give you surface resistivity by multiplying the surface resistance measurement in ohms by 10 to obtain surface resistivity in ohms/square. The PRF-911PT meets requirements from ANSI/ESD STM11.11, ANSI/ESD STM11.12 snd IEC 61340-2-3. It will also approximate surface and volume resistivity measurements per ASTM D-257.
-
ACUTRONIC Switzerland Ltd
Combining a 3-Axis Flight Motion Simulator (FMS) with a 2-Axis Target Motion Simulator (TMS) leads to a 5-Axis motion simulator design. This allows comprehensive HardWare-In-the-Loop tests (HWIL) for testing and development of guided missiles, munitions and other inertial systems. Almost 100% of all HWIL systems worldwide delivered over the last 50 years have been designed and built by ACUTRONIC and CARCO Electronics.
-
40-517-002 -
Pickering Interfaces Ltd.
The 40-515/516/517 2 Amp, 2-Pole Matrix Modules form part of the System 40 PXI ProgrammableSwitching system. Each module consists of a matrix of 64 2-pole electro-mechanicalrelays under the control of a PXI/PCI interface.These modules are designed for switching medium voltage/power signals in test applicationswhere reed relays do not have sufficient rating. They are also suitable for telecomsapplications where send and return signals need to be switched simultaneously.
-
40-516-002 -
Pickering Interfaces Ltd.
The 40-515/516/517 2 Amp, 2-Pole Matrix Modules form part of the System 40 PXI ProgrammableSwitching system. Each module consists of a matrix of 64 2-pole electro-mechanicalrelays under the control of a PXI/PCI interface.These modules are designed for switching medium voltage/power signals in test applicationswhere reed relays do not have sufficient rating. They are also suitable for telecomsapplications where send and return signals need to be switched simultaneously.
-
Scientific Research Corp. STI Division
SRC has developed a family of products used to test radar systems during development and to train after system implementation. Our product provides realistic signals at RF, IF, and at baseband that simulate multiple targets, jamming, atmospheric effects, and clutter. In addition to meeting U.S. needs, these radar environment simulators have been sold to customers in Spain, The Netherlands, and other countries to support key radar developments.
-
40-515-002 -
Pickering Interfaces Ltd.
The 40-515/516/517 2 Amp, 2-Pole Matrix Modules form part of the System 40 PXI ProgrammableSwitching system. Each module consists of a matrix of 64 2-pole electro-mechanicalrelays under the control of a PXI/PCI interface.These modules are designed for switching medium voltage/power signals in test applicationswhere reed relays do not have sufficient rating. They are also suitable for telecomsapplications where send and return signals need to be switched simultaneously.
-
KCTS-8000 -
Knopp Incorporated
The Knopp Current Transformer Testing System (Type KCTS-8000) is designed to measure the accuracy of instrument transformers having 1 or 5 ampere secondaries and primaries of up to 8000 amperes. The system uses a high accuracy multi-range current transformer as a reference standard. All ANSI standard burdens are included. The phase angle and ratio errors of the transformer-under-test (TUT) are measured by the built-in Knopp Automatic Transformer Comparator.
-
Bloomy Controls, Inc.
A Battery Management System (BMS) is an embedded unit performing critical battery functions, including cell monitoring and balancing, pack charge and discharge control, safety, and communications. The BMS must be tested early in development to optimize control algorithms, as well as during manufacturing to ensure reliable functionality. Bloomy’s family of BMS test systems provides a consistent platform for engineers to bring a BMS to market faster, and more reliably.
-
Ametek Scientific Instruments
Frequency Response Analysis (also referred to as Transfer Function Analysis) measures the output spectrum of a system relative to a stimulus, and is used to characterize the dynamics of the system under test. The technique measures the magnitude and phase relationship between output and input waveforms as a function of frequency. The input signals may be from a wide range of sensors including acoustic (microphones/sonar), mechanical (accelerometers/displacement transducers), optical (photodetectors), and electrical (amplifiers).
-
KCTS-8000 -
The Eastern Specialty Company
The Knopp Current Transformer Testing System (Type KCTS-8000) is designed to measure the accuracy of instrument transformers having 1 or 5 ampere secondaries and primaries of up to 8000 amperes. The system uses a high accuracy multi-range current transformer as a reference standard. All ANSI standard burdens are included. The phase angle and ratio errors of the transformer-under-test (TUT) are measured by the built-in Knopp Automatic Transformer Comparator.